Artículos 0
5225A
 
 

5225A

 

Programmable f/I-f/f converter

 

  • Pulse conditioning
  • Frequency generator
  • Concurrent f/I and f/f function
  • Analog current and voltage output
  • PNP / NPN output, optional relays
  • Programmable by PC and Loop Link
  1. Overview +

  2. Technical details +

  3. Accessories +


Advanced features

  • The 5225 transmitter can be configured with a standard PC and the Loop Link communications unit, or delivered fully configured.

Application

  • The f/I function performs frequency to current and voltage conversion.
  • The f/f function can be used for pulse division or multiplication and as a buffer collecting fast pulse trains.
  • The concurrent f/I and f/f functions enable a scaled digital output signal in conjunction with the analog output.
  • The frequency generator function is used as e.g. a time base or clock generator.
  • Input and supply polarity reversal protection.
  • Programmable digital outputs including NPN, PNP or relay options.

Technical characteristics

  • 4 front LEDs, indicating f in active inputs (not NPN), Dig.out.1 (NPN or relay 1) and Dig.out 2 (relay 2) outputs, and a NAMUR input error signal.
  • Analog current output can be configured to any current within 0...20 mA range.
  • Voltage output range is selectable between 0...10 VDC and 0...1 VDC by use of internal jumpers.
  • Input range:

    Frequency: 0...20,000 Hz

    Sensor types: NAMUR, tacho, NPN, PNP, TTL, S0

  • Output range:

    Current and voltage output: 0...20 mA / 0...10 V

    Relay outputs: 0...20 Hz

    NPN and PNP output as f/f: 0...1000 Hz

    NPN and PNP output as generator: 0...20,000 Hz

Environmental Conditions

  • Operating temperature

    -20°C to +60°C

  • Calibration temperature

    20...28°C

  • Relative humidity

    < 95% RH (non-cond.)

  • Protection degree

    IP20

Mechanical specifications

  • Dimensions (HxWxD)

    109 x 23.5 x 130 mm

  • Weight approx.

    190 g

  • DIN rail type

    DIN 46277

  • Wire size

    1 x 2.5 mm2 stranded wire

  • Screw terminal torque

    0.5 Nm

Common specifications

  • Supply

  • Supply voltage

    19.2...28.8 VDC

  • Max. required power

    3.5 W

  • Internal power dissipation

    1.7 W

  • Isolation voltage

  • PELV/SELV

    IEC 61140

  • Warm-up time

    30 s

  • Power-up delay

    0...999 s

  • Programming

    Loop Link

  • Signal / noise ratio

    Min. 60 dB

  • Response time, analog

    < 60 ms + period

  • Response time, digital output

    < 50 ms + period

  • Response time, concurrent f/I and f/f

    < 80 ms + period

  • Signal dynamics, output

    16 bit

  • Effect of supply voltage change

    < ±0.002% of span / %V

  • Auxiliary voltage: NAMUR supply

    8.3 VDC ±0.5 VDC / 8 mA

  • S0 supply

    17 VDC / 20 mA

  • NPN / PNP supply

    17 VDC / 20 mA

  • Special supply (programmable)

    5...17 VDC / 20 mA

  • Temperature coefficient

    < ±0.01% of span / °C

  • Linearity error

    < 0.1% of span

  • EMC immunity influence

    < ±0.5%

Input specifications

  • Common input specifications

  • Max. offset

    90% of selected max. frequency

  • Measurement range

    0...20 kHz

  • Min. measurement range

    0.001 Hz

  • Low cut-off frequency

    0.001 Hz

  • Max. frequency, with input filter ON

    50 Hz

  • Min. period time with input filter ON

    20 ms

  • Input types

    NAMUR acc. to DIN 19234

    Tacho

    NPN / PNP

    TTL

    S0 acc. to DIN 43864

Output specifications

  • Common output specifications

  • Updating time

    40 ms for concurrent f/I and f/f

    20 ms

  • Current output

  • Signal range

    0...20 mA

  • Min. signal range

    5 mA

  • Load (@ current output)

    ≤ 600 Ω

  • Load stability

    ≤ 0.01% of span / 100 Ω

  • Current limit

    < 23 mA

  • Voltage output

  • Signal range

    0...10 VDC

  • Min. signal range

    250 mV

  • Load (@ voltage output)

    ≥ 500 kΩ

  • Relay output

  • Max. switching frequency

    20 Hz

  • Isolation, test / working

    3.75 kVAC / 250 VAC

  • Max. voltage

    250 VRMS

  • Max. current

    2 AAC

  • Max. AC power

    500 VA

  • Max. load at 24 VDC

    1 A

  • Other output types

    Active outputs (NPN / PNP)

    f/f converter output

    Frequency generator

  • of span

    = of the presently selected range

Observed authority requirements

  • EMC

    2014/30/EU

  • LVD

    2014/35/EU

  • EAC

    TR-CU 020/2011

Su solicitud ha sido enviada con éxito - 0 Artículos en su lista
Descripción del producto Cantidad
Por favor, indique una variante ( véase ficha) - o indicar ' Variante desconocido '
Su información de contacto
Continuar navegando
No hay productos añadidos a la lista...
No tiene productos en su lista ...

Al navegar por las páginas de productos en este sitio web , tiene usted la posibilidad de añadir productos a una lista - y enviarnos su lista, solicitando con ello una oferta .
Para agregar productos a la lista , haga clic en el botón "consiga un presupuesto rápido " en las páginas de productos.

Cuando haya enviado la lista, nos pondremos en contacto con usted lo antes posible .

Si usted no presenta la lista,será visible para usted en el sitio web durante 7 días ( vamos a colocar una "cookie" en su PC o tablet ) .

Esperamos que usted encontrará la opcion útil . Por favor, vaya a las páginas de productos para agregar productos a su lista.
Gracias por su solicitud
Nos pondremos en contacto con usted por teléfono o correo electrónico tan pronto como sea posible.