Artículos 0
6337D
 
 

6337D

 

2-wire HART transmitter

 

  • 1- or 2-channel converter for RTD, TC, Ohm, and bipolar mV signals
  • 2 analog inputs and 5 device variables with status available
  • HART protocol revision selectable from HART 5 or HART 7
  • Hardware assessed for use in SIL applications
  • Mounting on a DIN rail in hazardous gas and dust area
  1. Overview +

  2. Technical details +

  3. Accessories +


Application

  • Linearized temperature measurement with TC and RTD sensors e.g. Pt100 and Ni100.
  • HART communication and 4...20 mA analog PV output for individual, difference or average temperature measurement of up to two RTD or TC input sensors.
  • Conversion of linear resistance to a standard analog current signal, e.g from valves or Ohmic level sensors.
  • Amplification of bipolar mV signals to standard 4...20 mA current signals.
  • Up to 63 transmitters (HART 7) can be connected in a multidrop communication setup.

Technical characteristics

  • HART protocol revision can be changed by user configuration to either HART 5 or HART 7 protocol.
  • The HART 7 protocol offers:
    ∙ Long Tag numbers of up to 32 characters.
    ∙ Enhanced Burst Mode and Event notification with time stamping.
    ∙ Device variable and status mapping to any dynamic variable PV, SV, TV or QV.
    ∙ Process signal trend measurement with logs and summary data.
    ∙ Automatic event notification with time stamps.
    ∙ Command aggregation for higher communication efficiency.
  • 6337D is designed according to strict safety requirements and is therefore suitable for applications in SIL installations.
  • Continuous check of vital stored data.
  • Meeting the NAMUR NE 21 recommendations, the 6337D HART transmitter ensures top measurement performance in harsh EMC environments. Additionally, the 6337D meets NAMUR NE43 and NE89 recommendations.

Mounting / installation

  • DIN rail mounting with up to 84 channels per meter.
  • Configuration via standard HART communication interfaces or by PR 5909 Loop Link.

Environmental Conditions

  • Operating temperature

    -40°C to +85°C

  • Storage temperature

    -40°C to +85°C

  • Calibration temperature

    20...28°C

  • Relative humidity

    < 95% RH (non-cond.)

  • Protection degree

    IP20

Mechanical specifications

  • Dimensions (HxWxD)

    109 x 23.5 x 104 mm

  • Weight (1 / 2 channels)

    150 / 200 g

  • DIN rail type

    DIN EN 60715/35 mm

  • Wire size

    0.13...2.08 mm2 AWG 26...14 stranded wire

  • Screw terminal torque

    0.5 Nm

Common specifications

  • Supply

  • Supply voltage

    8.0...30 VDC

  • Isolation voltage

  • Isolation voltage, test / working

    1.5 kVAC / 50 VAC

  • Response time

  • Response time (programmable)

    1...60 s

  • Voltage drop

    8.0 VDC

  • Programming

    Loop Link & HART

  • Accuracy

    Better than 0.05% of selected range

  • Signal / noise ratio

    > 60 dB

  • EMC immunity influence

    < ±0.1% of span

  • Extended EMC immunity: NAMUR NE21, A criterion, burst

    < ±1% of span

Input specifications

  • Common input specifications

  • Max. offset

    50% of selected max. value

  • RTD input

  • RTD type

    Pt50/100/200/500/1000; Ni50/100/120/1000

  • Cable resistance per wire

    5 Ω (up to 50 Ω per wire is possible with reduced measurement accuracy)

  • Sensor current

    Nom. 0.2 mA

  • Linear resistance input

  • Linear resistance min....max.

    0 Ω...7000 Ω

  • TC input

  • Thermocouple type

    B, E, J, K, L, N, R, S, T, U, W3, W5

  • Cold junction compensation (CJC)

    Constant, internal or external via a Pt100 or Ni100 sensor

  • Voltage input

  • Measurement range

    -800...+800 mV

  • Min. measurement range (span)

    2.5 mV

  • Input resistance

    10 MΩ

Output specifications

  • Current output

  • Signal range

    4…20 mA

  • Min. signal range

    16 mA

  • Load (@ current output)

    ≤ (Vsupply - 8) / 0.023 [Ω]

  • Sensor error indication

    Programmable 3.5…23 mA

  • NAMUR NE43 Upscale/Downscale

    23 mA / 3.5 mA

  • Common output specifications

  • Updating time

    440 ms

  • HART protocol revisions

    HART 7 and HART 5

Observed authority requirements

  • EMC

    2014/30/EU

Approvals

  • ATEX 2014/34/EU

    KEMA 09ATEX0148

  • IECEx

    DEK 11.0084X

  • FM

    FM17US0013X

  • CSA

    1125003

  • EAC Ex TR-CU 012/2011

    RU C-DK.GB08.V.00410

  • SIL

    Hardware assessed for use in SIL applications

Su solicitud ha sido enviada con éxito - 0 Artículos en su lista
Descripción del producto Cantidad
Por favor, indique una variante ( véase ficha) - o indicar ' Variante desconocido '
Su información de contacto
Continuar navegando
No hay productos añadidos a la lista...
No tiene productos en su lista ...

Al navegar por las páginas de productos en este sitio web , tiene usted la posibilidad de añadir productos a una lista - y enviarnos su lista, solicitando con ello una oferta .
Para agregar productos a la lista , haga clic en el botón "consiga un presupuesto rápido " en las páginas de productos.

Cuando haya enviado la lista, nos pondremos en contacto con usted lo antes posible .

Si usted no presenta la lista,será visible para usted en el sitio web durante 7 días ( vamos a colocar una "cookie" en su PC o tablet ) .

Esperamos que usted encontrará la opcion útil . Por favor, vaya a las páginas de productos para agregar productos a su lista.
Gracias por su solicitud
Nos pondremos en contacto con usted por teléfono o correo electrónico tan pronto como sea posible.