  • Input for RTD, TC, mV, linear resistance, mA, and V
  • 3-port 3.75 kVAC galvanic isolation
  • Current and voltage output
  • Universal voltage supply
  • 1- and 2-channel versions
  • Loop supply > 17.1 V
  1. Overview +

  2. Technical details +

  3. Accessories +


Advanced features

  • The 5114 transmitter can be configured using the PReset software and the Loop Link communications unit.

Application

  • Jumper selectable inputs for current/voltage or temperature.
  • Programmable current (0...100 mA) and voltage (0...250 VDC) inputs.
  • Linearized, electronic temperature measurement.
  • Conversion of linear resistance variation e.g, from solenoids and butterfly valves or linear movements with attached potentiometer.
  • 17.1 VDC loop and 2.5 VDC potentiometer supplies.
  • Automatic 4- / 3-wire or programmable 2-wire cable compensation.
  • Configurable sensor error detection including NAMUR NE43.

Technical characteristics

  • Active or Passive current output and selectable voltage output.
  • Separation of circuits in PELV/SELV installations.

Environmental Conditions

  • Operating temperature

    -20°C to +60°C

  • Calibration temperature

    20...28°C

  • Relative humidity

    < 95% RH (non-cond.)

  • Protection degree

    IP20

Mechanical specifications

  • Dimensions (HxWxD)

    109 x 23.5 x 130 mm

  • Weight approx.

    225 g

  • DIN rail type

    DIN 46277

  • Wire size

    1 x 2.5 mm2 stranded wire

  • Screw terminal torque

    0.5 Nm

Common specifications

  • Supply

  • Supply voltage, universal

    21.6...253 VAC, 50...60 Hz or 19.2...300 VDC

  • Fuse

    400 mA SB / 250 VAC

  • Max. required power

    2.1 W / 2.8 W (1 / 2 ch.)

  • Isolation voltage

  • Isolation voltage, test / working

    3.75 kVAC / 250 VAC

  • PELV/SELV

    IEC 61140

  • Response time

  • Temperature input, programmable (0...90%, 100...10%)

    400 ms...60 s

  • mA / V input (programmable)

    250 ms...60 s

  • Auxiliary supplies

  • 2-wire supply (pin 44...42 and 54...52)

    28...17.1 VDC / 0...20 mA

  • Programming

    Loop Link

  • Signal / noise ratio

    Min. 60 dB (0...100 kHz)

  • Accuracy

    Better than 0.05% of selected range

  • Updating time

    115 ms (temperature input)

    75 ms (mA / V / mV input)

  • Signal dynamics, input

    22 bit

  • Signal dynamics, output

    16 bit

  • Auxiliary voltages: Reference voltage

    2.5 VDC ±0.5% / 15 mA

  • EMC immunity influence

    < ±0.5% of span

  • Extended EMC immunity: NAMUR NE21, A criterion, burst

    < ±1% of span

Input specifications

  • Common input specifications

  • Max. offset

    50% of selected max. value

  • RTD input

  • RTD type

    Pt100, Ni100, lin. R

  • Cable resistance per wire

    10 Ω (max.)

  • Sensor current

    Nom. 0.2 mA

  • Effect of sensor cable resistance (3-/4-wire)

    < 0.002 Ω / Ω

  • Sensor error detection

    Yes

  • TC input

  • Thermocouple type

    B, E, J, K, L, N, R, S, T, U, W3, W5, LR

  • Cold junction compensation (CJC)

    < ±1.0°C

  • Sensor error current

    Nom. 30 μA

  • Sensor error detection

    Yes

  • Current input

  • Measurement range

    0...100 mA

  • Min. measurement range (span)

    4 mA

  • Input resistance: Supplied unit

    Nom. 10 Ω + PTC 10 Ω

  • Input resistance: Non-supplied unit

    RSHUNT = ∞, VDROP < 6 V

  • Voltage input

  • Measurement range

    0...250 VDC

    -150...+150 mV

  • Min. measurement range (span)

    5 mV

  • Input resistance

    Nom. 10 MΩ (≤ 2.5 VDC)

    Nom. 5 MΩ (> 2.5 VDC)

    Nom. 10 MΩ (mV input)

Output specifications

  • Current output

  • Signal range

    0...20 mA

  • Min. signal range

    10 mA

  • Load (@ current output)

    ≤ 600 Ω

  • Load stability

    ≤ 0.01% of span / 100 Ω

  • Current limit

    ≤ 28 mA

  • Sensor error indication

    Programmable 0...23 mA

  • NAMUR NE43 Upscale/Downscale

    23 mA / 3.5 mA

  • Passive 2-wire mA output

  • Signal range

    4...20 mA

  • Load stability

    ≤ 0.01% of span / 100 Ω

  • Max. load resistance [Ω]

    (Vsupply-3.5)/0.023 A

  • Max. external 2-wire supply

    29 VDC

  • Effect of external 2-wire supply voltage variation

    < 0.005% of span / V

  • Voltage output

  • Signal range

    0...10 VDC

  • Min. signal range

    500 mV

  • Load (@ voltage output)

    ≥ 500 kΩ

  • of span

    = of the presently selected range

Observed authority requirements

  • EMC

    2014/30/EU

  • LVD

    2014/35/EU

  • RoHS

    2011/65/EU

  • EAC

    TR-CU 020/2011

Approvals

  • DNV-GL Marine

    Stand. f. Certific. No. 2.4

Su solicitud ha sido enviada con éxito - 0 Artículos en su lista
Descripción del producto Cantidad
Por favor, indique una variante ( véase ficha) - o indicar ' Variante desconocido '
Su información de contacto
Continuar navegando
No hay productos añadidos a la lista...
No tiene productos en su lista ...

Al navegar por las páginas de productos en este sitio web , tiene usted la posibilidad de añadir productos a una lista - y enviarnos su lista, solicitando con ello una oferta .
Para agregar productos a la lista , haga clic en el botón "consiga un presupuesto rápido " en las páginas de productos.

Cuando haya enviado la lista, nos pondremos en contacto con usted lo antes posible .

Si usted no presenta la lista,será visible para usted en el sitio web durante 7 días ( vamos a colocar una "cookie" en su PC o tablet ) .

Esperamos que usted encontrará la opcion útil . Por favor, vaya a las páginas de productos para agregar productos a su lista.
Gracias por su solicitud
Nos pondremos en contacto con usted por teléfono o correo electrónico tan pronto como sea posible.